American DJ Galaxian Royale Instruction Manual Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 10
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
©American DJ® - www.americandj.com - Galaxian Royale Instruction Manual Page 8©American DJ® - www.americandj.com - Galaxian Royale Instruction Manual Page 7
Galaxian Royale Set Up
Power Supply: Before plugging your unit in, be sure the source volt-
age in your area matches the required voltage for your American DJ®
Galaxian Royale.™ The American DJ® Galaxian Royale has a swit-
chable voltage of 115v or 220v. Because line voltage may vary from
venue to venue, you should be sure your unit voltage matches the wall
outlet voltage before attempting to operate you xture. Also be sure
to only use the included I.E.C. power cable supplied with the unit, this
cable matches the voltage and current requirements of the unit.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used by most lighting and controller manufactures as a form of
communication between intelligent fixtures and controllers. A DMX
controller sends DMX data instructions from the controller to the fix-
ture. DMX data is sent as serial data that travels from fixture to fixture
via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX
fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of
different manufactures to be linked together and operate from a sin-
gle controller, as long as all xtures and the controller are DMX com-
pliant. To ensure proper DMX data transmission, when using several
DMX fixtures try to use the shortest cable path possible. The order
in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1
may be placed anywhere in a DMX line, at the beginning, at the end,
or anywhere in the middle. Therefore, the first fixture controlled by the
controller could be the last fixture in the chain. When a fixture is as-
signed a DMX address of 1, the DMX controller knows to send DATA
assigned to address 1 to that unit, no matter where it is located in the
DMX chain.
Data Cable (DMX Cable) Requirements (For
DMX and Master/Slave Operation): The Galaxian
Royale can be controlled via DMX-512 protocol.
The Galaxian Royale is a 4 channel DMX unit. The
DMX address is set electronically using the con-
trols on the top rear panel of the unit. Your unit and
your DMX controller require a approved DMX-512
110 Ohm Data cable for data input and data output
(Figure 1). We recommend Accu-Cable DMX cables. If you are making
Figure 1
Galaxian Royale Laser Warning Labels
LASER RADIATION AVOID
DIRECT EYE EXPOSURE
Maximum output <5 mW
Wavelength: 405, 532nm
Class IIIa laser product
This device complies with 21 CFR chapter I,
Subchapter J, or CFR 1040.10 and 1040.11
LA SE R R A DIA TIO N A VO ID
DIR EC T E Y E E X PO SU RE
Ma ximu m ou tput < 5 m W
Wa ve len gth : 4 05 , 5 32 nm
Cla ss III a l as e r pr o d uc t
Th is devic e c o mpli es wi th 21 CF Rc ha pter I ,
Su bc h apte r J , o r C F R 10 40. 10 an d 1 040.11
Specication label